WPC 2XBXIPEnglishSIMetric XX T I. A. 1. a.(1)(a) i) a) 1 .1 A. 1. a. 1) a) a)TX` hp x (#%'0*,.8135@8: SHEET METAL ROOFING`(#V076100 > Petersen Aluminum Corp.  1005 Tonne Rd. # Elk Grove Village, IL 60007 # Phone: (800) 3231960  Phone: (847) 2287150  Fax: (800) 7227150  www.pacclad.com  This MANUSPEC utilizes the Construction Specifications Institute (CSI) Project Resource Manual (PRM), including MasterFormatTM, SectionFormatTM and PageFormatTM. A MANUSPEC is a manufacturerspecific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets []; delete optional text in final copy of specification. Specifier Notes precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion. I This MANUSPEC specifies factoryformed metal wall, soffit and roof panels. These products are manufactured by Petersen Aluminum Corp. Revise MANUSPEC section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles. I SECTION 076100 SHEET METAL ROOFING PART 1 GENERAL 1.1 SUMMARY  A.Section Includes: This Section specifies factoryformed metal wall, soffit and roof panels.  B.Related Sections:   1.` Section [ ______ ]. 1.2 REFERENCES  A.ASTM International:   1.` ASTM A653/A653 Standard Specification for Steel Sheet, ZincCoated (Galvanized) or ZincIron AlloyCoated (Galvannealed) by the HotDip Process.   2.` ASTM A792/A792M Standard Specification for Steel Sheet, 55% AluminumZinc AlloyCoated by the Hot Dip Process.   3.` ASTM B209 Standard Specification for Aluminum and AluminumAlloy Sheet and Plate.   4.` ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.   5.` ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference.   6.` ASTM E1592 Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference.   7.` ASTM E1646 Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference.   8.` ASTM E1680 Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems.  B.FM Global (Factory Mutual):   1.` FM Class I90.  C.Sheet Metal and Air Conditioning Contractor's National Association (SMACNA):   1.` SMACNA Architectural Sheet Metal Manual.  D.Underwriters Laboratories, Inc. (UL):   1.` UL 263 Fire Tests of Building Construction and Materials.   2.` UL 580 Tests for Uplift Resistance of Roof Assemblies.   3.` UL 790 Standard Test Methods for Fire Tests of Roof Coverings.   4.` UL 1897 Uplift Tests for Roof Covering Systems.   5.` UL 2218 Impact Resistance of Prepared Roof Covering Materials. 1.3 SYSTEM DESCRIPTION  A.Materials:   1.` G90 hotdipped galvanized Grade A structural quality steel in compliance with ASTM A653.   2.` Alloy 3105 [ H14 ] [ H34 ] aluminum panels in compliance with ASTM B209.   3.` Coldrolled copper.  B.Performance Requirements:   1.` Wind uplift in compliance with UL Classification 580 for UL Classified 90 rated assemblies.   2.` Static air infiltration of 0.06 cfm/sf (0.028 liters/second) with 6.24 psi (43 kPa) air pressure differential as tested in accordance with ASTM E283.   3.` No water infiltration at inward static air pressure differential of not less than 6.24 psi (43 kPa) and not more than 12 psi (83 kPa) as tested in accordance with ASTM E331. 1.4 ACTION SUBMITTALS  A.General: Submit listed action submittals in accordance with Conditions of the Contract and Section [ 01 33 00 Submittal Procedures ] [ ______ ].  B.Shop Drawings: Indicate information on shop drawings as follows:   1.` Layout, profiles and product components including dimensions, anchorage, erection details, flashing details, elevations, plans and sections required to indicate conditions.  C.Samples: Submit as follows:   1.` [ Duplicate ] [ ______ ], [ 12 inch x 12 inch (305 x 305 mm) ] [ ______ ] samples of each [ Roofing ] [ Soffit ] [ Wall panel ] [ ______ ] [ And ] [ Flashing ] product to show selected [ Colors ] [ Finishes ] [ Textures ] used on project.  D.Product Data: Submit product data, including manufacturer's SPECDATA product sheet, for specified products.   1.` Material Safety Data Sheets (MSDS). 1.5 INFORMATION SUBMITTALS  A.Quality Assurance:   1.` Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties.   2.` Certificates: Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements.   3.` Manufacturer's Instructions: Manufacturer's installation instructions.  B.Manufacturer's Field Reports: Manufacturer's field reports specified. 1.6 CLOSEOUT SUBMITTALS  A.Warranty: Submit warranty documents specified.  B.Operation and Maintenance Data: Submit operation and maintenance data for installed products in accordance with Section [ 01 78 00 Closeout Submittals ] [ ______ ].   1.` Include:   ` a.@ Manufacturer's instructions covering maintenance requirements. 1.7 QUALITY ASSURANCE  A.Qualifications:   1.` Installer experienced in performing work of this section who has specialized in installation of work similar to that required for this project.   2.` Manufacturer Qualifications: Manufacturer capable of providing field service representation during construction and approving erection method.  B.Regulatory Requirements:   1.` FM Class I90.   2.` SMACNA Architectural Sheet Metal Manual.   3.` UL 263.   4.` UL 580.   5.` UL 790.   6.` UL 1897.   7.` UL 2218.  C.Preinstallation Meetings: Conduct preinstallation meeting to verify project requirements, manufacturer's installation instructions and manufacturer's warranty requirements. Comply with [ Section 01 31 19 Project Meetings ] [ ______ ]. 1.8 DELIVERY, STORAGE & HANDLING  A.General: Comply with [ 01 61 00 Common Product Requirements ] [ ______ ].  B.Ordering: Comply with manufacturer's ordering instructions and lead time requirements to avoid construction delays.  C.Delivery:   1.` Deliver materials in manufacturer's original packaging with identification labels intact.  D.Storage and Protection:   1.` Store materials protected from exposure to harmful weather conditions and at temperature conditions recommended by manufacturer.   2.` Stack prefinished material to prevent twisting, bending, abrasion, scratching and denting.   3.` Elevate one end of each skid to allow for moisture runoff.   4.` Prevent contact with material that may cause corrosion, discoloration or staining.   5.` Provide factory installed strippable vinyl film protective coating to panels.  E.Waste Management and Disposal:   1.` Separate waste materials for [ Reuse ] [ And ] [ Recycling ] [ _____ ] in accordance with [ Section 01 74 19 Construction Waste Management and Disposal ] [ _____ ].   2.` Remove from site and dispose of packaging materials at appropriate recycling facilities.   3.` Collect and separate for disposal [ Paper ] [ Plastic ] [ Polystyrene ] [ Corrugated cardboard ] [ _____ ] packaging material [ In appropriate onsite bins ] [ _____ ] for recycling. 1.9 PROJECT AMBIENT CONDITIONS   A.Installation Location: Assemble and erect components only when temperatures are above 40 degrees F (4 degrees C).  1.10SEQUENCING   A.Sequence With Other Work: Comply with manufacturer's written recommendations for sequencing construction operations.  1.11WARRANTY   A.Project Warranty: Refer to Conditions of the Contract for project warranty provisions.   B.Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty document executed by authorized company official. Manufacturer's warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents.   C.Warranty: Commencing on date of acceptance by [ Owner ] [ Architect ] [ Consultant ] [ _____ ].  1.12MAINTENANCE   A.Comply with manufacturer's written instructions to maintain installed product.  1.13EXTRA MATERIALS   A.Provide maintenance materials in accordance with Section [ 01 78 00 Closeout Submittals ] [ ______ ]. PART  2 PRODUCTS 2.1 MANUFACTURERS  A.Ensure manufacture has minimum [ 5 ] [ ______ ] years experience in manufacturing components similar to or exceeding requirements of project. 2.2 SHEET METAL ROOFS, SOFFITS, WALL PANELS, TILES  A.Manufacturer: Petersen Aluminum Corp.   1.` Contact: 1005 Tonne Rd., Elk Grove Village, IL 60007; Telephone: (800) 3237960, (847) 2287150; Fax: (800) 7227150; website: www.pacclad.com.  B.Proprietary Products/Systems:   1.` Roof Panels [ RP1 ] [ ______ ]:   ` a.@ Panel Description: [ TITELOC ] [ TITELOC HS ] [ TITELOC PLUS ].   ` @ 1) Width: [ 12 inches (305 mm) ] [ 16 inches (406 mm) ] [ 17 5/8 inches (448 mm) ] [ 18 inches (457 mm) ].   ` @ 2) Height: 2 inches (51 mm).   ` b.@ Panel Description: SNAPCLAD Standing Seam.   ` @ 1) Width: [ 10 inches (254 mm) ] [ 12 inches (305 mm) ] [ 16 inches (406 mm) ] [ 18 inches (457 mm) ].   ` @ 2) Height: 1 3/4 inches (45 mm).   ` c.@ Panel Description: SNAPON Standing Seam.   ` @ 1) Width: [ 12 inches (305 mm) ] [ 16 inches (406 mm) ] [ 18 inches (457 mm) ] [ 20 inches (508 mm) ].   ` @ 2) Height: 1 inch (25.4 mm).   ` d.@ Panel Description: High SNAPON Standing Seam.   ` @ 1) Width: [ 11 inches (279 mm) ] [ 18 inches (457 mm) ] [ 19 inches (483 mm) ].   ` @ 2) Height: 1 1/2 inches (38.1 mm).   ` e.@ Panel Description: SNAPON Batten.   ` @ 1) Width: [ 11 inches (279 mm) ] [ 12 inches (305 mm) ] [ 18 inches (457 mm) ].   ` @ 2) Height: 1 1/2 inches (38.1 mm).   ` f.@ Panel Description: RediRoof Standing Seam.   ` @ 1) Width: [ 12 inches (305 mm) ] [ 16 inches (406 mm) ] [ 18 inches (457 mm) ] [ 20 inches (508 mm) ].   ` @ 2) Height: 1 9/16 inches (40 mm).   ` g.@ Panel Description: RediRoof Batten.   ` @ 1) Width: 12 inches (305 mm).   ` @ 2) Height: 1 1/4 inches (32 mm).   ` h.@ Material: [ 22 gauge (0.85 mm) hotdipped galvanized steel ] [ 24 gauge (0.70 mm) hotdipped galvanized steel ] [ 0.032 inch (0.81 mm) aluminum alloy 3105H14 ] [ 0.040 inch (1.02 mm) aluminum alloy 3105H14 ] [ 16 oz (0.45 kg) cold rolled copper ].   ` i.@ Type: [ Standing seam ] [ High snapon standing seam ] [ Batten ] [ With offsets ].   `  j.@ Radius: [ Concave ] [ Convex ] available in TITELOC, SNAPON Standing Seam and RediRoof Batten.   `  k.@ Sealant: Factory applied and available on TITELOC, TITELOC HS, TITELOC PLUS and SNAPCLAD Standing Seam.   `  l.@ Striations (optional).   `  m.@ Stiffening Beads: [ None ] [ 1 ] [ 2 ] [ 3 ] manufacturer applied.   `  n.@ Texture: [ Smooth ] [ Stucco embossed ].   ` o.@ Topside Panel Finish: [ From manufacturer's standard colors ] [ _____ ].   ` p.@ Panel Underside Finish: Polyester wash coat with dry film thickness of 0.3 mil.   ` q.@ Eave notched.   2.` Wall Panels [ WP1 ] [ ______ ]:   ` a.@ Panel Description: Flush Panel.   ` @ 1) Width: [ 7 inches (178 mm) ] [ 11 inches (279 mm) ] [ 12 inches (305 mm) ] [ 18 inches (457 mm) ].   ` @ 2) Height: 1 inch (25.4 mm).   ` b.@ Panel Description: Reveal Panel.   ` @ 1) Width: [ 7 inches (178 mm) ] [ 11 inches (279 mm) ] [ 18 inches (457 mm) ].   ` @ 2) Height: 1 inch (25.4 mm).   ` c.@ Panel Description: MPanel.   ` @ 1) Width: [ 36 inches (914 mm) ] [ 42 inches (1067 mm) ].   ` @ 2) Height: 3/4 inch (19.1 mm).   ` d.@ Panel Description: RPanel.   ` @ 1) Width: [ 36 inches (914 mm) ] [ 41 inches (1041 mm) ].   ` @ 2) Height: 1 1/4 inch (32 mm).   ` e.@ Panel Description: 7/8 inch (22.2 mm) Panel.   ` @ 1) Width: Variable.   ` @ 2) Height: 1 1/2 inches (38.1 mm).   ` f.@ Panel Description: 1/2 inch (12.7 mm) Panel.   ` @ 1) Width: 40 inches (1016 mm).   ` @ 2) Height: 1/2 inch (12.7 mm).   ` g.@ Panel Description: 7.2 Rib Panel.   ` @ 1) Width: 36 inches (914 mm).   ` @ 2) Height: 1 1/2 inches (38.1 mm).   ` h.@ Material: [ 22 gauge (0.85 mm) hotdipped galvanized steel ] [ 24 gauge (0.70 mm) hotdipped galvanized steel ] [ 0.032 inch (0.81 mm) aluminum alloy 3105H14 ] [ 0.040 inch (1.02 mm) aluminum alloy 3105H14 ].   ` i.@ Stiffening Beads: Number [ None ] [ 1 ] [ 2 ] [ 3 ] manufacturer applied.   `  j.@ Texture: [ Smooth ] [ Stucco embossed ].   `  k.@ Venting: [ Nonvented ] [ 1 row ] [ 2 rows ] available on Flush Panels.   `  l.@ Topside Panel Finish: [ From manufacturer's standard colors ] [ _____ ].   `  m.@ Panel Underside Finish: Polyester wash coat with dry film thickness of 0.3 mil.    3.` Soffit Panels [ SP1 ] [ _____ ]:   ` a.@ Panel Description: Flush Panel.   ` @ 1) Width: [ 7 inches (178 mm) ] [ 11 inches (279 mm) ].   ` @ 2) Height: 1 inch (25.4 mm).   ` @ 3) Material: [ 22 gauge (0.85 mm) hotdipped galvanized steel ] [ 24 gauge (0.70 mm) hotdipped galvanized steel ] [ 0.032 inch (0.81 mm) aluminum alloy 3105H14 ] [ 0.040 inch (1.02 mm) aluminum alloy 3105H14 ].   ` b.@ Panel Description: Reveal Panel.   ` @ 1) Width: [ 7 inches (178 mm) ] [ 11 inches (279 mm) ].   ` @ 2) Height: 1 inch (25.4 mm).   ` @ 3) Material: [ 22 gauge (0.85 mm) hotdipped galvanized steel ] [ 24 gauge (0.70 mm) hotdipped galvanized steel ] [ 0.032 inch (0.81 mm) aluminum alloy 3105H14 ] [ 0.040 inch (1.02 mm) aluminum alloy 3105H14 ].   ` c.@ Panel Description: PAC750 Soffit Panel.   ` @ 1) Width: 12 inches (305 mm).   ` @ 2) Height: 1/2 inch (12.7 mm).   ` @ 3) Material: 0.032 inch (0.81 mm) aluminum alloy 3105H14.   ` d.@ Panel Description: PAC850 Soffit Panel.   ` @ 1) Width: 12 inches (305 mm).   ` @ 2) Height: 1/2 inch (12.7 mm).   ` @ 3) Material: 0.032 inch (0.81 mm) aluminum alloy 3105H14.   ` e.@ Stiffening Beads: Number [ None ] [ 1 ] [ 2 ] [ 3 ] manufacturer applied.   ` f.@ Texture: [ Smooth ] [ Stucco embossed ].   ` g.@ Venting: [ Full Vent ] [ Half Vent ].   ` h.@ Venting: [ Nonvented ] [ 1 row ] [ 2 rows ].   ` i.@ Topside Panel Finish: [ From manufacturer's standard colors ] [ _____ ].   `  j.@ Panel Underside Finish: Polyester wash coat with dry film thickness of 0.3 mil.    4.` Tiles [ TP1 ] [ _____ ]:   ` a.@ Material: [ Copper coated ] [ Zinctitanium ].   ` b.@ Tile Dimension: 39 3/8 inches x 13 3/8 inches (1000 x 340 mm).   ` c.@ Acceptable Material: Petersen Aluminum Corp. PacClad Tegola [ Prestige Elite ] [ Prestige Compact ] [ Prestige Traditional ] [ ZT Compact ] [ ZT Prestige PrePatina Elite ] [ ZT Prestige PrePatina Compact ] Tiles.   5.` Flashing and Trim:   ` a.@ Material: [ 0.033 inch (0.85 mm) hotdipped galvanized steel ] [ 0.027 inch (0.70 mm) hotdipped galvanized steel ] [ 0.032 inch (0.81 mm) ] [ 0.040 inch (1.02 mm) ] [ 0.051 inch (1.29 mm) ] [ 0.064 inch (1.63 mm) ] [ 0.080 inch (2.05 mm) alloy 3105H14 aluminum ] [ 16 oz (0.45 kg) cold rolled copper ].   ` b.@ Profiles: [ To manufacturer's standard flashing and trim profiles ] [ As detailed ] [ _____ ].   ` c.@ [ Color and finish to match [ Roof ] [ Wall ] [ Soffit ] [ Tile ] panels ] [ _____ ]. 2.3 SOURCE QUALITY CONTROL  A.Ensure cladding/roofing components and materials are from single manufacturer. 2.4 PRODUCT SUBSTITUTIONS  A.Substitutions: [ In accordance with Section 01 25 13 Product Substitution Procedures ] [ ______ ] [ No substitutions permitted ]. PART 3 EXECUTION 3.1 MANUFACTURER'S INSTRUCTIONS  A.Compliance: Comply with manufacturer's written data, including product technical bulletins, product catalog installation instructions, product carton installation instructions and Petersen Aluminum Corp. PACCLAD SPECDATA sheets. 3.2 EXAMINATION  A.Site Verification of Conditions:   1.` Verify that substrate conditions, which have been previously installed under other sections or contracts, are acceptable for product installation in accordance with manufacturer's instructions prior to installation of [ Roof ] [ Wall ] [ Soffit ] [ Tile ] panels. 3.3 PREPARATION  A.Ensure surfaces are clean and free of dirt and other foreign matter harmful to performance of [ Roof ] [ Wall ] [ Soffit ] [ Tile ] materials.  B.Remove manufacturer's protective film from panel surfaces.  C.Coordinate panel installation with work of other trades to provide a noncorrosive and leakproof installation.  D.Prevent galvanic action of dissimilar metals in proximity to one another. 3.4 INSTALLATION  A.Seams: Provide uniform, neat seams.  B.Fasteners: Conceal fasteners where possible in exposed work. Cover and seal fasteners and anchors for watertight and leakproof installation.  C.SealantType Joints: Provide sealanttype joint where indicated. Form joints to conceal sealant. 3.5 FIELD QUALITY CONTROL  A.Have manufacturer of products supplied under this Section review work involved in handling, installation/application, protection and cleaning of its product(s), and submit written reports in acceptable format to verify compliance of work with Contract.  B.Manufacturer's Field Services: Provide manufacturer's field services consisting of product use recommendations and periodic site visits for inspection of product installation in accordance with manufacturer's instructions.  C.Schedule Site Visits to Review Work at Stages Listed:   1.` After delivery and storage of products, and when preparatory Work on which Work of this Section depends is complete, but before installation begins.   2.` [ Twice ] [ ______ ] during progress of Work at [ 25% ] [ ______ ] and [ 60% ] [ ______ ] complete.   3.` Upon completion of Work, after cleaning is carried out.  D.Obtain reports within [ 3 ] [ ______ ] days of review and submit. 3.6 TESTING AND VERIFICATION  A.Perform tests recommended and required by manufacturer to verify required performance of panel system, under supervision and monitoring process of accredited and designated design engineer.  B.Perform and meet tests required by [ Owner ] [ Architect ] [ Consultant ] [ Authorities having jurisdiction ] [ ______ ]. 3.7 FINAL CLEANING  A.Do cleanup in accordance with Section [ 01 74 00 Cleaning and Waste Management ] [ ______ ].  B.Upon completion, remove surplus and excess materials, rubbish, tools and equipment. 3.8 PROTECTION s Specifier Note: Coordinate the following Article with Section 01 76 00 Protecting Installed Construction. s  A.Protect installed product from damage during construction in accordance with Section [ 01 76 00 Protecting Installed Construction ] [ ______ ]. 3.9 SCHEDULE e Specifier Note: Include a schedule of panel types and locations to suit project requirements. e   A.Roof Panel Type RP1: [ Location ].   B.Roof Panel Type RP2: [ Location ].   C.Wall Panel Type WP1: [ Location ].   D.Soffit Panel Type SP1: [ Location ].   E.Tile Type TP1: [ Location ]. END OF SECTION