WPC 2XBXIPEnglishSIMetric XX T I. A. 1. a.(1)(a) i) a) 1 .1 A. 1. a. 1) a) a)TX` hp x (#%'0*,.8135@8: HOLLOW METAL FRAMES`(#V081213 >' Studco Building Systems US, LLC ' 545 Basket Road  Webster, NY 14580  Phone: (800) 6758023  Phone: (585) 2659450  Fax: (585) 2656678 & Email: mail@studcosystems.com & www.ezyjamb.com  This MANUSPEC utilizes the Construction Specifications Institute (CSI) Project Resource Manual (PRM) including MasterFormatTM, SectionFormatTM and PageFormatTM. A MANUSPEC is a manufacturerspecific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets []; delete optional text in final copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion. F This MANUSPEC specifies a trimless, slittype door frame system. This product is manufactured by Studco Building Systems US, LLC. Revise MANUSPEC section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat( for other section numbers and titles. F SECTION 081213 HOLLOW METAL FRAMES PART 1 GENERAL 1.1 SUMMARY  A.Related Sections:   1.` Installation of Doors: Division 08 Doors Sections.   2.` Finish Hardware: Division 08 Finish Hardware Sections. 1.2 REFERENCES  A.ASTM International (ASTM):   1.` ASTM A653 Standard Specification for Steel Sheet, ZincCoated (Galvanized) or ZincIron AlloyCoated (Galvannealed) by the HotDip Process.  B.National Fire Protection Association (NFPA):   1.` NFPA 80 Fire Doors and Windows.   2.` NFPA 252 Fire Tests of Door Assemblies.  C.Underwriters Laboratories, Inc. (UL):   1.` UL 10C Positive Pressure Fire Tests of Door Assemblies.  D.Underwriters' Laboratories of Canada (ULC):   1.` ULC CAN4S104M80 Standard Method for Fire Tests of Door Assemblies. 1.3 SUBMITTALS  A.General: Submit listed submittals in accordance with Conditions of the Contract and Section [ 01 33 00 Submittal Procedures ] [ ______ ].  B.Product Data: Submit product data, including manufacturer(s SPECDATA sheet, for specified products.  C.Shop Drawings: Submit drawings showing details of each opening, including elevations, frame profiles, finishes, accessories, hardware and anchorage.  D.Samples:   1.` Frames: Submit samples of manufacturer(s full range of standard colors for specified finish(es).   ` a.@ For each color selected, submit 12 inch (305 mm) long samples.   2.` Hinges: For each finish selected, submit 6 inch (152 mm) square samples.  E.Quality Control Submittals:   1.` Manufacturer(s Instructions: Manufacturer(s installation instructions. 1.4 QUALITY ASSURANCE  A.Regulatory Requirements:   1.` In accordance with Section [ 01 41 00 Regulatory Requirements ] [ ______ ].   2.` Firerated steel frames shall be of types tested and approved by Intertek Testing Services, Warnock Hersey and shall bear labels of same. Threesided frames shall receive a permanent Mylar 90 minute label. Sidelite and borrowed lite frames shall receive a Mylar Warnock Hersey label when specified.  B.Fire Resistance Rating: As indicated on drawings, tested and listed by:   1.` [ UL 10C ].   2.` [ NFPA 80 ].   3.` [ NFPA 252 ].   4.` [ ULC CAN 4 S104 ]. 1.5 DELIVERY, STORAGE & HANDLING  A.General: Comply with Section [ 01 61 00 Common Product Requirements ] [ ______ ].  B.Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.  C.Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions recommended by the manufacturer.   1.` Store material in a protected area, under cover, on wooden skids. Keep material vented to avoid condensation until ready for installation. PART 2 PRODUCTS 2.1 HOLLOW METAL FRAMES  A.Manufacturer: Studco Building Systems US, LLC.   1.` Contact: 545 Basket Road, Webster, NY 14580; Telephone: (800) 6758023, (585) 2659450; Fax: (585) 2656678; Email: mail@studcosystems.com; website: www.ezyjamb.com.  B.EZYJamb:   1.` Door Types and Sizes: As indicated on drawings. 2.2 MATERIALS  A.Steel Sheet: ASTM A653, zinciron alloy coated (G60 galvannealed). 2.3 ACCESSORIES  A.Reveal: EZY Reveal.  B.Cap: EZY Cap.  C.Hinges: [ Butt type ] [ Invisible type ].   1.` Finish: [ Stainless steel ] [ Satin chrome ] [ Satin brass ] [ Oilrubbed bronze ] [ Polished chrome ] [ Polished brass ]. 2.4 FABRICATION  A.Door Frames:   1.` Frame members shall be of a double rabbet profile with integral stops. Construct jam member to interlock and align with header members to form a strong joint.  B.Sidelite and Borrowed Lite Frames:   1.` Construct as specified for door frames. Where required, provide concealed fieldapplied mullion clips for securing mullions to head/jamb members.   2.` Form fixed glazing stops integral with frame members.   3.` Provide removable metal stops with prepunched screw holes complete with installation screws.  C.Factory Finishing:   1.` Finish door frames, sidelite and borrowed lites as follows:   ` a.@ Prime finished, suitable for field applied finish paint in the standard gray prime color.   ` b.@ Prefinished with factoryapplied baked enamel.   ` c.@ Color: [ As selected from the manufacturer(s standard colors ] [ Custom color to match Architect(s sample ]. 2.5 PRODUCT SUBSTITUTIONS  A.Substitutions: Substitutions in accordance with Section [ 01 25 13 Product Substitution Procedures ] [ No substitutions permitted ] [ ______ ]. PART 3 EXECUTION 3.1 MANUFACTURER(S INSTRUCTIONS  A.Compliance: Comply with manufacturer(s product data, including product technical bulletins, product catalog installation instructions and product carton instructions for installation. 3.2 EXAMINATION  A.Site Verification of Conditions: Verify that substrate conditions, for substrates previously installed under other sections, are acceptable for product installation in accordance with manufacturer's instructions. 3.3 PREPARATION  A.Adjacent Surfaces Protection: Protect adjacent work areas and finish surfaces from damage during product installation.  B.Surface Preparation: Contact manufacturer. 3.4 INSTALLATION  A.Install frames plumb and square, in accordance with shop drawings and manufacturer's instructions. Verify opening and dimension with shop drawings. Use door as a template to ensure proper alignment and clearances. T Specifier Note: Retain article below only if hinges are specified in Part 2. T  B.Attach hinges and hang door in frame. Adjust frame to door for equal and uniform clearance between top and sides of door and frame.  C.Secure frame to wall with the appropriate type fasteners and install casing on frame. 3.5 ADJUSTING  A.Repair or replace damaged or defective frames.  B.Touch up damaged areas of factoryapplied finishes with aerosol spray cans of same paint as used in factory. 3.6 CLEANING  A.Proceed in accordance with Section [ 01 74 23 Final Cleaning ] [ ______ ].  B.Upon completion and verification of performance of installation, remove surplus materials, excess materials, rubbish, tools and equipment. 3.7 PROTECTION  A.Protection: Protect installed product and finish surfaces from damage during construction. END OF SECTION