WPC 2XBXIPEnglishSIMetric XX T I. A. 1. a.(1)(a) i) a) 1 .1 A. 1. a. 1) a) a)TX` hp x (#%'0*,.8135@8: SOLAR CONTROL FILMS`(#V088713 >8 3MTM Building Safety Solutions Window Film 8( 3M Center, Building 0223 02524 (! Saint Paul, MN 551441000 ! Phone: (800) 4301704  Phone: (651) 7371053  www.3m.com/windowfilm  This MANUSPEC utilizes the Construction Specifications Institute (CSI) Project Resource Manual (PRM), including MasterFormatTM, SectionFormatTM and PageFormatTM. A MANUSPEC is a manufacturerspecific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets []. Delete optional text in final copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion.  This MANUSPEC specifies solar control window films. These products are manufactured by 3M. Revise MANUSPEC section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles.  SECTION 088713 SOLAR CONTROL FILMS PART 1 GENERAL 1.1 REFERENCES  A.ASTM International (ASTM):   1.` ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials.   2.` ASTM E308 Standard Practice for Computing the Colors of Objects by Using the CIE System.   3.` ASTM E903 Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres. 1.2 DEFINITIONS  A.Luminous Efficacy: The ratio of visible light transmission to shading coefficient. 1.3 SYSTEM DESCRIPTION  A.Performance Requirements:   1.` Fire Performance: Surface burning characteristics when tested in accordance ASTM E84:   ` a.@ Flamespread: 25, maximum.   ` b.@ Smoke Developed: 450, maximum. 1.4 SUBMITTALS  A.General: Submit listed submittals in accordance with Conditions of the Contract and Section [ 01 33 00 Submittal Procedures ] [ ___________ ].  B.Product Data: Submit product data, including manufacturer's SPECDATA sheet, for specified products.  C.Samples: Submit 8 1/2 x 11 inch (216 x 279 mm) samples of specified film(s).  D.Quality Control Submittals:   1.` Certificates: Manufacturer(s certification that the installer is acceptable.   2.` Manufacturer(s Instructions: Manufacturer's installation instructions.  E.Closeout Submittals:   1.` Warranty: Manufacturer's standard warranty document executed by authorized company official. Manufacturer's warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents. 1.5 QUALITY ASSURANCE  A.Installer Qualifications: Acceptable to the manufacturer.  B.Regulatory Requirements: In accordance with Section [ 01 41 00 Regulatory Requirements ] [ ______ ]. 1.6 DELIVERY, STORAGE & HANDLING  A.General: Comply with Section [ 01 61 00 Common Product Requirements ] [ ______ ].  B.Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.  C.Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions recommended by the manufacturer. 1.7 WARRANTY  A.Project Warranty: Refer to Conditions of the Contract for project warranty provisions.  B.Manufacturer's Warranty: Submit, in accordance with Section [ 01 78 36 Warranties ] [ ______ ] for Owner(s acceptance, manufacturer's standard warranty document executed by authorized company official. Manufacturer's warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents.   1.` Warranty Period: 15 years commencing on Date of Substantial Completion. PART 2 PRODUCTS 2.1 SOLAR CONTROL FILMS  A.Manufacturer: 3M.   1.` Contact: 3MTM Building Safety Solutions Window Film, 3M Center, Building 022302524, Saint Paul, MN 551441000; Telephone: (800) 4301704, (651) 7371053; website: www.3m.com/windowfilm.  B.Prestige 70 Clear Film:   1.` Thickness: 2 mils.   2.` Physical Properties When Film Is Applied to 1/4 Inch (6.4 mm) Thick Clear Glass:   ` a.@ Visible Light Transmission (ASTM E903, ASTM E308): 68% when measured with an integrating sphere spectrometer and calculated using Standard Source "C" for average daylight.   ` b.@ Visible Reflection Exterior (ASTM E903): Not more than 9%.   ` c.@ Visible Reflection Interior (ASTM E903): Not more than 9%.   ` d.@ Ultraviolet Rejected (ASTM E903): Not less than 99.9%.   ` e.@ Infrared Energy Rejected (ASTM E903): Not less than 97%.   ` f.@ Luminous Efficacy: Not less than 1.17.   ` g.@ Shading Coefficient at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 0.58.   ` h.@ Total Solar Energy Rejected (TSER) at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 50%.   ` i.@ Total Solar Energy Rejected (TSER) at 60 Degrees (ASTM E903): Not less than 59%.   C.Prestige 60 Clear Film:   1.` Thickness: 2 mils.   2.` Physical Properties When Film Is Applied to 1/4 Inch (6.4 mm) Thick Clear Glass:   ` a.@ Visible Light Transmission (ASTM E84): 61%.   ` b.@ Visible Reflection Exterior (ASTM E903): Not more than 8%.   ` c.@ Visible Reflection Interior (ASTM E903): Not more than 8%.   ` d.@ Ultraviolet Rejected (ASTM E903): Not less than 99.9%.   ` e.@ Infrared Energy Rejected (ASTM E903): Not less than 97%.   ` f.@ Luminous Efficacy: Not less than 1.11.   ` g.@ Shading Coefficient at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 0.55.   ` h.@ Total Solar Energy Rejected (TSER) at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 52%.   ` i.@ Total Solar Energy Rejected (TSER) at 60 Degrees (ASTM E903): Not less than 61%.   D.Prestige 50 Lightly Tinted Film:   1.` Thickness: 2 mils.   2.` Physical Properties When Film Is Applied to 1/4 Inch (6.4 mm) Thick Clear Glass:   ` a.@ Visible Light Transmission (ASTM E84): 50%.   ` b.@ Visible Reflection Exterior (ASTM E903): Not more than 8%.   ` c.@ Visible Reflection Interior (ASTM E903): Not more than 7%.   ` d.@ Ultraviolet Rejected (ASTM E903): Not less than 99.9%.   ` e.@ Infrared Energy Rejected (ASTM E903): Not less than 97%.   ` f.@ Luminous Efficacy: Not less than 0.98.   ` g.@ Shading Coefficient at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 0.51.   ` h.@ Total Solar Energy Rejected (TSER) at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 56%.   ` i.@ Total Solar Energy Rejected (TSER) at 60 Degrees (ASTM E903): Not less than 63%.   E.Prestige 40 Lightly Tinted Film:   1.` Thickness: 2 mils.   2.` Physical Properties When Film Is Applied to 1/4 Inch (6.4 mm) Thick Clear Glass:   ` a.@ Visible Light Transmission (ASTM E84): 39%.   ` b.@ Visible Reflection Exterior (ASTM E903): Not more than 7%.   ` c.@ Visible Reflection Interior (ASTM E903): Not more than 6%.   ` d.@ Ultraviolet Rejected (ASTM E903): Not less than 99.9%.   ` e.@ Infrared Energy Rejected (ASTM E903): Not less than 97%.   ` f.@ Luminous Efficacy: Not less than 0.83.   ` g.@ Shading Coefficient at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 0.47.   ` h.@ Total Solar Energy Rejected (TSER) at 90 Degrees (Normal Incidence) (ASTM E903): Not less than 59%.   ` i.@ Total Solar Energy Rejected (TSER) at 60 Degrees (ASTM E903): Not less than 66%.  2.2 PRODUCT SUBSTITUTIONS  A.Substitutions: Substitutions in accordance with Section [ 01 25 13 Product Substitution Procedures ] [ No substitutions permitted ] [ ______ ]. PART 3 EXECUTION 3.1 MANUFACTURER'S INSTRUCTIONS  A.Compliance: Comply with manufacturer's product data, including product technical bulletins, product catalog installation instructions and product carton instructions for installation. 3.2 EXAMINATION  A.Site Verification of Conditions: Verify that substrate conditions for substrates that have been previously installed under other sections are acceptable for product installation in accordance with manufacturer's instructions. 3.3 CLEANUP  A.Proceed in accordance with Section [ 01 74 23 Final Cleaning ] [ ______ ].  B.Upon completion and verification of performance of installation, remove surplus materials, excess materials, rubbish, tools and equipment. END OF SECTION