WattStopper lighting control devices offer energy savings, convenience, flexibility, information, productivity, safety and security, as well as advanced energy efficiency for sustainability programs. With solutions that satisfy both occupant and mandatory energy codes requirements, WattStopper offers digital lighting management, occupancy sensors, daylighting controls, room controllers, personal controls, lighting control panels and plug load controls for energy management.

DIGITAL LIGHTING MANAGEMENT

The WattStopper Digital Lighting Management (DLM) System is an intelligent, distributed control system that maximizes lighting energy efficiency. Consisting of intelligent room controllers, occupancy sensors, switches, daylighting sensors, plug load controls, lighting control panels, interfaces and accessories, DLM provides convenient, energy-saving control of dimmed and switched loads. Devices can be personalized, and sensors and switches feature two-way infrared (iR) communication that allows control from a handheld remote. System components connect with Category 5e cables with RJ-45 connectors. DLM can be used for stand-alone control of individual building spaces or for centralized control of a floor, building or entire campus. Features include:

  • Infrared (iR) transceiver for bi-directional communication
  • On/off and dimming control options
  • Handheld remotes for personal control
  • Easy-to-read LCD displays
  • Easy personalization with Push 'n Learn™
  • Multiple local networks can be connected for centralized monitoring and management

OCCUPANCY SENSORS

  • LMPC-100 Low Profile Digital PiR Corner Mount Occupancy Sensor - Part of a WattStopper Digital Lighting Management (DLM) system, this digital sensor uses passive infrared (PIR) technology and one of two coverage pattern options to detect occupancy in different types of spaces for energy efficient control of lighting and, optionally, plug loads.
  • LMUC-100 Low Profile Digital Ultrasonic Ceiling Mount Occupancy Sensor - Part of a WattStopper DLM system, this digital sensor uses ultrasonic standing wave analysis technology for 360 degree occupancy sensing.
  • LMDC-100 Digital Dual Technology Ceiling Mount Occupancy Sensor - Part of a WattStopper DLM system, the LMDC-100 is a digital sensor that uses passive infrared (PIR) and ultrasonic technologies for precise occupancy sensing.
  • LMPX-100 Digital PIR Corner Mount Occupancy Sensor - The LMPX-100 digital sensor, part of a WattStopper DLM system, uses passive infrared (PIR) technology and one of four coverage pattern options to detect occupancy for energy-efficient control of lighting and, optionally, plug loads.
  • LMDX-100 Digital Dual Technology Corner Mount Occupancy Sensor - The LMDX-100, part of a WattStopper DLM system, uses both passive infrared (PIR) and ultrasonic technologies to achieve precise occupancy sensing for energy efficient control of lighting and, optionally, plug loads.

DAYLIGHTING CONTROLS

  • LMLS-400 Single Zone Switching and Dimming Closed Loop Digital Photosensor - This closed loop photosensor measures the level of ambient light to automatically switch or dim lighting zones. An optional part of a WattStopper DLM system, it sends light level signals to control loads that are connected to DLM on/off or dimming room controllers. The LMLS-400 has a photodiode with an extended range of 1-10,000 footcandles (fc) and photopic correction for precise measurement of visible light.
  • LMLS-105 On/Off Photosensor - This single zone switching device is designed for closed loop daylighting applications. It includes an advanced digital multi-band photosensor that turns off light to prevent false triggers, an on-board microcontroller and an LCD display. The LMLS-105 has an extended range of 1-1,400 footcandles and is an optional part of a WattStopper Digital Lighting Management (DLM) system.
  • LMLS-500 Multi-zone Switching and Dimming Open Loop Digital Photosensor - The LMLS-500 is an open loop, multi-zone photosensor that measures daylight contribution to automatically switch or dim as many as three zones of lighting. As an optional part of a DLM system, it sends light level signals to control loads connected to DLM on/off or dimming room controllers. The LMLS-500 has a photodiode with an extended range of 1-10,000 footcandles (fc) and photopic correction for precise measurement of visible light.
  • LMLS-305 0-10 Volt Dimming Photosensor - This single zone ceiling-mounted device works with standard 0-10 VDC electronic dimming ballasts to dim lighting as the ambient light level increases. It is an optional part of a WattStopper DLM system and is designed for closed loop daylighting applications.

NETWORK COMPONENTS

  • LMBC-300 Digital Network Bridge - The LMBC-300 Digital Network Bridge provides a segment network connection for multiple DLM local network devices, enabling individual DLM local networks to be aggregated into a larger system, which, in turn, can be remotely managed from a DLM Segment Manager or a building automation system (BAS).
  • LMSM-ENC1 Enclosure for LMSM Segment Manager

SpecData datasheets available for downloadBIM Objects

Switch Wall Digital 8 Button LMSW 108 WattStopper Wireless Config Tool LMCT 100 WattStopper
Switch Wall Digital 5 Button LMSW 105 WattStopper Switch Wall Digital 4 Button LMSW 104 WattStopper
Switch Wall Digital 3 Button LMSW 103 WattStopper Switch Wall Digital 2 Button LMSW 102 WattStopper
Switch Wall Digital 1 Button LMSW 101 WattStopper Switch Light Ultrasonic Sensor 2 Relay UW 200 WattStopper
Switch Light Ultrasonic Sensor 1 Relay UW 100 WattStopper Switch Light Passive Infrared 1 Relay PW 100 WattStopper
Switch Light Passive Infrared 2 Relay PW 200 WattStopper Switch Light Dual Infrared Ultrasonic 2 Relay DW 200 WattStopper
Switch Light Dimming Digital LMDM 101 WattStopper Switch Light Dual Infrared Ultrasonic 1 Relay DW 100 WattStopper
Splitter Cable 1 In 2 Out LMRJ S8 WattStopper Room Controller Dimming 3 Relay LMRC 213 WattStopper
Room Controller Dimming 2 Relay LMRC 212 WattStopper Room Controller Dimming 1 Relay LMRC 211 WattStopper
Room Controller Dimming w Bridge 2 Relay LMRC 312 WattStopper Room Controller Dimming w Bridge 3 Relay LMRC 313 WattStopper
Room Controller Dimming w Bridge 1 Relay LMRC 311 WattStopper Room Controller Digital 2 Relay LMRC 102 WattStopper
Room Controller Digital 1 Relay LMRC 101 WattStopper Room Controller Digital Plug LMPL 101 WattStopper
Room Controller Digital Plug Load LMPL 201 WattStopper Photosensor Switching Dimming Multi Zone LMLS 500 WattStopper
Photosensor Single Zone LMLS 105 WattStopper Photosensor Switching Dimming LMLS 400 WattStopper
Photosensor Dimming 10 Volt LMLS 305 WattStopper Occupancy Sensor Corner Passive Infrared LMPX 100 WattStopper
Occupancy Sensor Corner Infrared Ultrasonic LMDX 100 WattStopper Occupancy Sensor Ceiling Ultrasonic LMUC 100 WattStopper
Occupancy Sensor Ceiling Passive Infrared LMPC 100 WattStopper Occupancy Sensor Ceiling Infrared Ultrasonic LMDC 100 WattStopper
Light Control Digital Photocell Input Module LMPO 200 WattStopper Light Control Digital Photocell Input Module LMPS 6000 WattStopper
Light Control Digital Network Segment Manager LMSM 603 WattStopper Light Control Digital Photocell Input Module LMIO 301 WattStopper
Light Control Digital Network Segment Manager LMSM 201 WattStopper Coupler Cable End to End LMRJ C8 WattStopper
Infrared Receiver Ceiling LMIR 100 WattStopper Light Control Digital Input Output Interface LMIO 101 WattStopper
Light Control Digital Network Bridge LMBC 300 WattStopper Control Panel Lighting LILM 8 WattStopper
Control Panel Lighting LILM 48 WattStopper Control Panel Lighting LILM 24 WattStopper

 

click here to update your log-in and member information

click here to maintain your company profile & view metrics

Manufactured By
2800 De La Cruz Blvd.
Santa Clara, CA 95050-2619
Phone:
(408) 988-5331
Tollfree:
(800) 879-8585
Fax:
(408) 988-5373
Documents Available
MasterFormat® Categorization
03 00 00 - Concrete
04 00 00 - Masonry
05 00 00 - Metals
08 00 00 - Openings
09 00 00 - Finishes
10 00 00 - Specialties
11 00 00 - Equipment
12 00 00 - Furnishings
21 00 00 - Fire Suppression
22 00 00 - Plumbing
23 00 00 - HVAC
26 00 00 - Electrical
27 00 00 - Communications
31 00 00 - Earthwork
33 00 00 - Utilities
34 00 00 - Transportation